Browse all practice questions for the ESCO Refrigeration Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

ESCO Refrigeration Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • In a DX evaporator system, the refrigerant enters the evaporator as
  • Zero psia is:
  • What is the typical state of refrigerant in the suction line?
  • When diagnosing a compressor that won't start, which step best aligns with a proper starting-issue checklist?
  • Which method can be used for leak detection with all high-pressure refrigerants?
  • When an AXV is used as a metering device, a low refrigerant charge will cause...
  • Which of the following is not a symptom of a hermetic system that is low on refrigerant?
  • Which statement correctly describes high-side and low-side pressures and subcooling?
  • A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms...
  • The main function of the condenser in a refrigeration system is to remove heat from the refrigerant.
  • A restriction in the metering device can cause which evaporator condition?
  • The first function the condenser must perform is to ___ the refrigerant before condensing can occur.
  • Why is unobstructed condenser airflow crucial?
  • In a vacuum of 28 inches of mercury, at what temperature will water begin to vaporize?
  • Heat added to a vapor after the change of state is called?
  • Three basic types of condensers are water cooled, air cooled, and ___ cooled.
  • Which of the following describes proper PPE and lockout/tagout practices when servicing refrigeration equipment?
  • Which condition indicates the presence of frost on the suction line?
  • A dirty evaporator in an air conditioning system will cause these symptoms...
  • Which device is used to prevent evaporator pressure from falling below a set limit?
  • A compressor that has a broken Reed valve will cause these symptoms...
  • What is the function of the evaporator in a vapor-compression refrigeration system?
  • Which condition would you expect from an overcharged refrigerant in a capillary tube system?
  • Why is a vacuum applied to the isolated section before re-pressurizing after service?
  • What is the generally accepted range for evaporator air flow in cfms per ton of residential air conditioning?
  • What is the function of the condenser in a vapor-compression refrigeration system?
  • Which of the following statements best describes the evaporator airflow requirement for residential AC?
  • Which component is primarily part of the high-side circuit in a typical refrigeration system?
  • Which sequence correctly describes how to calculate evaporator outlet superheat?
  • A decrease in superheat causes the TXV to begin to
  • Liquid line sweating near the dryer is most likely caused by:
  • A rise in evaporator pressure causes the AXV to begin to
  • Which statement is not true about a capillary tube metering device?
  • What is the function of a low-pressure switch in a compressor-controlled system and what fault conditions could trigger it?
  • Which statement describes the function of an oil separator in a refrigeration system?
  • Frost on the suction line indicates:
  • What is the recommended evacuation procedure to remove moisture from a system?
  • A low refrigerant charge in a system using both TEV and capillary tube will cause which pressure change?
  • A centrifugal compressor is typically associated with which of the following characteristics?
  • If the line temperature is 70°F and the pressure corresponds to a saturated suction temperature of 42°F, what is the system's superheat?
  • A decrease in superheat causes the TXV to begin to
  • What is the typical target superheat for common residential systems?
  • Which symptom would indicate an oil-logged condenser?
  • A compound pressure gauge measures
  • What is the purpose of the receiver in a vapor-compression refrigeration system?
  • What is the purpose of the metering device in a vapor-compression refrigeration cycle?
  • In testing the efficiency of an air-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving air temperature?
  • A liquid to suction heat exchanger is often used to...
  • Which of the following types of air conditioning compressors is most energy efficient?
  • A low pressure cut-off switch is used to...
  • Which statement is not true about capillary tube metering devices?
  • Capillary tube metering devices are described as which type of restriction?
  • To remove as much moisture as possible from a system, what evacuation procedure is recommended?
  • Which of the following best describes the typical relationship between evaporator outlet and inlet temperatures in a TXV system?
  • A faulty condenser fan motor on an air conditioning system will cause these symptoms...
  • Which of the following is a common cause of compressor short cycling and how would you diagnose it?
  • Compare R-407C and R-404A in terms of typical applications and operating temperatures.
  • When a TEV or a capillary tube is used as a metering device, a low refrigerant charge will cause...
  • Compared to R22 systems, the flow rate of a thermostatic expansion valve (TEV) in a 410A system is approximately what?
  • How can you tell if the condensate drain is blocked and what steps fix it?
  • What is the minimum vertical drop from the outlet of the condensate drain pan to the inlet of the P trap?
  • Why is an inline filter-drier used and where is it placed in the system?
  • ___ can be used for leak detection with ALL high pressure refrigerants.
  • How should you prevent refrigerant oil from contaminating the suction line and what precautions apply when opening or brazing?
  • The temperature at which moisture will start to condense from the air is called
  • What role does cylinder fill percentage play in refrigerant handling and what safety precautions should be followed?
  • Which methods remove moisture from a refrigeration system?
  • Which factor does a TXV primarily respond to in regulating refrigerant flow?
  • The evaporator's function is to:
  • In the evaporator, the refrigerant absorbs latent heat from the space which causes it to
  • After observing a liquid line leak repair and system recharge, a noisy, hot compressor likely indicates which problem?
  • In a water-cooled condenser scenario, 10 lbs of refrigerant loses 20 BTU per lb, and 10 lbs of water passes through with the entering water at 80°F. What is the water leaving temperature?
  • A TXV has three operating pressures...
  • Differentiating evaporator and condenser coils, where heat transfer occurs and what state changes take place?
  • A thermal-electric (solid state) expansion valve is controlled by
  • What is a potential consequence of moisture in a refrigeration system?
  • Before leak testing, what is a critical safety/environmental precaution you should take?
  • Which fault is most likely to cause high suction pressure and high discharge pressure in an air conditioning system?
  • In the energy balance example, the heat gained by the water equals the heat lost by the refrigerant.
  • Removing the cut off plate from a blower assembly would most directly affect which parameter?
  • Which action best removes solid contaminants after a severe hermetic compressor burnout?
  • Distinguish between refrigerant reclaim, recycling, and recap, and describe when each is required.
  • An overcharge of refrigerant will cause:
  • What steps should you take to verify system cleanliness after brazing or major repairs?
  • For an R410A system with a gauge reading of 124 psig and a suction line temperature of 54°F, what is the operating superheat?
  • A refrigerant gives up heat when:
  • Which indicators signal moisture in a refrigeration system and how can moisture compromise performance?
  • Water enters a condenser at 80°F and leaves at 100°F; what is the water temperature rise?
  • Which statement best contrasts electric defrost and hot-gas defrost in terms of heat source and typical use?
  • Which statement best describes compressor types and their typical characteristics?
  • During condensation, the refrigerant releases heat to the surroundings.
  • Air or other noncondensable gases in a capillary tube air conditioning system will cause these symptoms.
  • At a residential service call with no cooling and unit completely out of refrigerant, the technician decides to use a trace amount of refrigerant and ___ in order to pressurize the system
  • Which type of expansion valve is described as solid-state and controlled by an NTC parameter?
  • The AXV is designed to maintain...
  • What is the function of a metering device in a refrigeration system?
  • How is superheat adjusted on many metering devices?
  • Why is adequate airflow across the evaporator essential, and what are common causes of restricted airflow?
  • Which statement correctly describes the evaporator pressure regulating valve (EPR)?
  • Fan airflow pressures are usually measured in...
  • The heat removed from the refrigerant by the condenser is which type of heat?
  • In which applications is R-404A typically used?
  • A low refrigerant charge in an air conditioning system will cause these symptoms...
  • Which OSHA electrical-safety standards apply to HVAC technicians working on energized equipment?
  • A partially iced over evaporator can be caused by...
  • An overcharge of refrigerant will cause which condition?
  • Why is purging lines with dry nitrogen during brazing important?
  • How can you tell if a system uses R-410A versus R-22 from labeling and service data, and why does it matter for pressures?
  • What is the purpose of a crankcase heater and when should it be energized?
  • A decrease in superheat causes the TXV to
  • Which condition is commonly associated with a low refrigerant charge in the system?
  • When charging a system, how do you decide whether to use the superheat method or the subcooling method?
  • The temperature rise method of determining air volume is applicable to which equipment?
  • What is the state of refrigerant entering the condenser?
  • Which safety attribute is a key reason for keeping refrigerant cylinders upright and away from heat?
  • While troubleshooting a residential split system, the service technician finds low operating pressures and low system amperage draw. This could be an indication of:
  • Which electrical checks help prevent compressor overload?
  • Which term describes heat transfer during vaporization?
  • When mounting a TXV sensor bulb, which of the following is NOT true
  • Electric defrost and hot-gas defrost cycles operate and what are practical differences?
  • Which is not a thermodynamic property of refrigerants?
  • Solid contaminants such as sludge and carbon, from a severe hermetic compressor motor burnout are best removed...
  • Which statement is not true of a capillary tube metering device?
  • Bubbles in the sight glass could indicate which condition in a system using a thermostatic expansion valve?
  • Which of the following accurately describes EPA requirements for refrigerant recovery?
  • Where should the liquid line filter dryer be installed in a typical DX system?
  • In a direct expansion evaporator system, the refrigerant entering the evaporator is best described as
  • The AXV best suited for operation under which condition?
  • A customer complains their air conditioning system runs constantly but does not cool well, the suction line is very cold and the compressor is sweating. The most likely cause is:
  • Which oils are commonly used in refrigerant systems, and what steps help prevent cross-contamination when replacing oil?
  • Which maintenance step helps prevent compressor overload in hot weather conditions?
  • A OF a TEV bulb that has detached from the suction line will typically produce which pressure condition?
  • Which practice helps ensure the correct oil type is used after service?
  • What is a typical purpose of a liquid-to-suction heat exchanger in refrigeration systems?
  • An inefficient compressor is usually indicated by ___ head pressure and ___ suction pressure.
  • Capillary tube metering devices are best described as
  • Which of the following cannot be used as a low ambient temperature control?
  • Why should nitrogen be used to pressurize or purge a system prior to leak testing and brazing?
  • If the cut off plate is removed from a blower assembly, how would this effect blower performance?
  • An air conditioning system that is oversized can cause...
  • What is the role of an accumulator in the oil return path?
  • When connecting copper to steel, the recommended brazing filler alloy is a...
  • The oil pressure safety switch is operated by...
  • When using an electronic leak detector, at what rate should the sensor probe be moved to survey for leaks?
  • A liquid receiver is used to
  • When topping off an operating system containing a blended refrigerant, how should the refrigerant be introduced?
  • What is a microchannel coil and what are its advantages and maintenance considerations?
  • Why is refrigerant-oil compatibility important and what steps should you take when replacing oil?
  • Which statement defines the dew point temperature?
  • An inefficient compressor is usually indicated by which combination of head and suction pressures?
  • What are common methods for leak testing refrigerant circuits and what precautions should you take?
  • In an R134a system, the high pressure gauge reads 143 psig and the liquid line temperature at the condensing unit is 95°F. What is the operating system superheat?
  • What does the sensing bulb of a TXV/EVV do and where should it be placed?
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature relative to the inlet is usually
  • A mechanical shaft seal is necessary on a...
  • Which vacuum level is typically targeted when evacuating a system to remove moisture?
  • Before servicing a system, what equipment is required to handle refrigerant safely?
  • What type of gauge is used to measure microns?
  • Which statement about capillary tubes is true?
  • Why is nitrogen or dry purge used during brazing of refrigerant piping?
  • List common reasons for a system to display low refrigerant charge and how to verify each.
  • Which component has no moving parts and is commonly used as a fixed restriction in metering?
  • Subcooling is defined as which of the following?
  • What is the primary purpose of a service valve in a refrigeration system?
  • In the evaporator, latent heat transfer occurs as the refrigerant boils and absorbs heat
  • A system with a leak in the liquid line was repaired, evacuated, and recharged. When started, the compressor is noisy and running hot. The most probable cause is...
  • What is the purpose of a liquid-line filter-drier and where should it be installed?
  • An accumulator is used to
  • Where would a sight glass normally be located in a refrigerant system?
  • A TEV bulb which becomes detached from the suction line will cause these symptoms...
  • After installing a new system, describe a standard charging procedure using the superheat method and what data to record.
  • In a basic vapor-compression refrigeration cycle, which component is responsible for raising the pressure and temperature of the refrigerant vapor?
  • Which option is NOT a TXV operating pressure?
  • What is the primary purpose of an accumulator?
  • Why is proper documentation of service data and test results important in refrigeration work?
  • Between which components is the liquid line filter dryer installed?
  • In an air conditioning system that uses a TXV, the evaporator outlet temperature is usually
  • Which statement best describes the regulatory guidance for reclaim, recycling, and recap of refrigerants?
  • How is subcooling measured, and what does it indicate about system performance?
  • Which refrigerant is HCFC and commonly used in older residential HVAC systems?
  • The purpose of an evaporator pressure regulating valve (EPR) is to...
  • How does UV dye leak detection work and what color indicates a leak under UV light?
  • What is the purpose of a micron gauge in vacuum testing of refrigeration systems?
  • A low refrigerant charge in a system with an AXV metering device will result in which condition?
  • Which parameter does the oil pressure safety switch monitor?
  • Before opening a vapor compression system for service, what must be done with the refrigerant?
  • Which statement about capillary tubes is true?
  • Back seating a two-way service valve results in which condition?
  • What is refrigerant recovery efficiency and why is it important for compliance?
  • If excess refrigerant is charged into a system, the result is typically
  • How does humidity affect evaporator frosting and energy efficiency?
  • Which loads should the evaporator coil design primarily address?
  • What pressure is sensed by the TXV's sensing bulb?
  • Provide approximate normal high-side and low-side pressure ranges for R-410A at typical outdoor temperatures.
  • In the evaporator, latent heat is transferred from the refrigerated space to the refrigerant.
  • The clearance space in a reciprocating compressor
  • In an air conditioning system that uses a thermostatic expansion valve, the temperature of the evaporator outlet will usually be...
  • An increase in head pressure causes ___ refrigerant to flow through a capillary tube.
  • What maintenance consideration is particularly important for microchannel coils?
  • In a pump-down system, where is the solenoid valve located?
  • What is a typical result of an incorrect refrigerant charge?
  • What is oil return and how do suction-side components help ensure it?
  • Which statement about slight suction-line superheat is true?
  • What is the function of a receiver in a refrigeration system, and when is a receiver used?
  • A TXV is designed to maintain...
  • Which gauge is used to measure vacuum at the micron level in HVAC systems?
  • Using a manifold gauge set, high-pressure readings primarily indicate which system area?
  • Which statement best describes the condenser inlet state?
  • How is superheat defined?
  • Which condition is typically observed when a TEV bulb becomes detached from the suction line?
  • In the condenser example, the BTU transferred by the water is
  • A residential split system had a compressor replaced last week; now the unit is not cooling properly. The evaporator seems starved of refrigerant. The liquid line is sweating where it leaves the dryer. This is most likely the result of:
  • Which statement best describes a thermostatic expansion valve and a capillary tube in terms of control, efficiency, and operating range?
  • In testing the efficiency of a water-cooled condenser, the refrigerant condensing temperature should be no more than approximately how many degrees higher than the leaving water temperature?
  • Refrigerant R-134a vapor enters the condenser at 124 psig, 100°F and leaves at 80°F. Its pressure will be approximately...
  • A partially clogged capillary tube can cause which evaporator condition?
  • What are safe practices for handling refrigerant cylinders, including weight checks and storage?
  • Which of the following is a typical sign of a malfunctioning TXV/EEV?
Subscribe

Get the latest from Passetra